Eaton AGC-1/2-R Fast-Blow Glass Fuse 500 mA 250 Vac
Eaton AGC-1/2-R Fast-Blow Glass Fuse 500 mA 250 Vac

Eaton AGC-1/2-R Fast-Blow Glass Fuse 500 mA 250 Vac

Share
pEaton AGC-1/2-R — 500 mA, 250 V, fast-acting glass cartridge fuse, 35 A at 250 Vac; 10,000 A at 125 Vac; 1,000 A at 32 Vac interrupting./p
    • Product Details
    • Download

    Eaton AGC-1/2-R Fast-Blow Glass Fuse 500 mA 250 Vac

    Built by Eaton, the AGC-1/2-R carries 500 mA, rated 250 Vac, uses a fast-acting element, in a glass body.

    Technical Data

    ParameterRating
    Part numberAGC-1/2-R
    Typical voltage drop0.324 V
    Design standardUL 248-14
    BodyGlass tube, 1/4 x 1-1/4 in (6.3 x 32 mm)
    Elementsingle element
    Typical melting I2t0.385 A²s
    Voltage rating250 Vac
    Typical DC cold resistance0.483 Ω
    End capsnickel-plated brass
    AC interrupting rating35 A at 250 Vac; 10,000 A at 125 Vac; 1,000 A at 32 Vac
    Rated current500 mA (1/2 A)

    Selection Notes

    • Interrupting capability is 35 A at 250 Vac; 10,000 A at 125 Vac; 1,000 A at 32 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 500 mA to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Q&A

    What are the ratings of the AGC-1/2-R?

    500 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac; 10,000 A at 125 Vac; 1,000 A at 32 Vac.

    Is the AGC-1/2-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the AGC-1/2-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at 250 Vac; 10,000 A at 125 Vac; 1,000 A at 32 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.