| Parameter | Rating |
|---|---|
| Part number | AGC-40-R |
| Breaking capacity | 35 A at 250 Vac up to 3 A, 100 A at 250 Vac from 1-1/4 A, 1,000 A at 32 Vac |
| Body | Glass tube, 1/4 x 1-1/4 in (6.3 x 32 mm) |
| Typical DC cold resistance | 0.0016 Ω |
| Typical voltage drop | 0.125 V |
| End caps | nickel-plated brass |
| Voltage rating | 32 Vac |
| Typical melting I2t | 11,360 A²s |
| AC interrupting rating | 1,000 A at 32 Vac |
| Design standard | UL 248-14 |
| Element | single element |
| Rated current | 40 A |
Engineers usually specify it for these duties:
What are the ratings of the AGC-40-R?
40 A continuous at 32 Vac, interrupting rating 1,000 A at 32 Vac.
Is the AGC-40-R fast-acting or time-delay?
It is fast-acting. Expect it to open quickly on overload.
Can the AGC-40-R be used on a higher fault-current circuit?
No — its interrupting rating is 1,000 A at 32 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.