    At 1.5 A, AHC-1-5-R is the rating most often picked when the measured load lands just under the next step up in the AHC range.

    Core Specifications

    ParameterValue
    Manufacturer / SeriesEaton / AHC Series
    Part numberAHC-1-5-R
    Current rating1.5 A
    Voltage rating600 Vac / 600 Vdc
    Interrupting rating (AC)10,000 A @ 600 Vac
    Interrupting rating (DC)10,000 A @ 600 Vdc
    Typical resistance250 mΩ
    Typical voltage drop550 mV @ rated current
    Package1/4 x 1-1/4 in (6.3 x 32 mm) ceramic tube, cartridge or axial lead
    Agency / environmentalcURus recognition file E19180, guide JDYX2 and JDYX8; RoHS compliant and halogen free

    Electrical Characteristics

    % of rating / conditionOpening time
    1.0 In4 hours minimum
    2.5 In120 seconds maximum

    At 1.5 A

    • Heat at this rating. 550 mV drop across 1.5 A works out to 0.825 W in the element; the cold resistance of 0.25 Ohm would suggest only 0.5625 W, so the rest is the element's own temperature rise. Layout the copper for the higher figure.
    • Interruption. 10,000 A at the rated voltage is what this part is tested to clear. Above that the enclosure rather than the element decides what happens, so the prospective fault current is part of the application check, not only the load.
    • Position in the range. Sits between AHC-1-R and AHC-1-6-R in the range. Stepping down to AHC-1-R trips sooner on light overload but leaves less continuous headroom; AHC-1-6-R trades the other way.

    Where 1.5 A Fits

    1.5 A is normally specified for desktop and appliance power inlets - single-phase equipment inlets and adapter outputs. If the measured steady current already sits within 20 % of 1.5 A, the next rating up in the same body is the safer release.

    For Procurement

    • Order AHC-1-5-R. The orderable reference on this page reads AHC-1-5-R; the packaging prefix, where the series uses one, goes in front of the part number rather than after it.
    • Agency / compliance for this rating: cURus recognition file E19180, guide JDYX2 and JDYX8; RoHS compliant and halogen free.
    • 1.5 A is not interchangeable with the neighbouring rating beyond its name: the current, the terminal arrangement and the body dimensions all have to match.

    Frequently Asked Questions

    Will AHC-1-5-R carry 1.5 A continuously without opening?
    Yes. The published table shows no opening at 100 % of rating, so 1.5 A is inside the continuous rating at 25 C. Ambient temperature inside the enclosure, not the nominal current, is what usually forces the next size up.

    What fault current can AHC-1-5-R clear?
    10,000 A at rated voltage. That figure assumes a normal branch-circuit source impedance; a stiff transformer feeding the same circuit can exceed it, and then the fuse is no longer the protective device by design.

    Can AHC-1-5-R replace the next rating up in an existing design?
    No. Dropping from a higher rating changes both the continuous headroom and the I2t, so a fuse that used to ride through inrush may now open on it. Match current, voltage, I2t and body before substituting.

    Design note: resistance, I2t and voltage-drop values are typical unless identified as ratings. Verify the current data sheet and curves before release.