Eaton AHC-6-R 6 A 600 Vac High Voltage Fast-Acting Ceramic Tube Fuse
Eaton AHC-6-R 6 A 600 Vac High Voltage Fast-Acting Ceramic Tube Fuse

Eaton AHC-6-R 6 A 600 Vac High Voltage Fast-Acting Ceramic Tube Fuse

Share
pEaton AHC-6-R — 6 A, 600 V, fast-acting ceramic cartridge fuse, 10,000 A @ 600 Vac interrupting./p
    • Product Details
    • Download

    Eaton AHC-6-R 6 A 600 Vac High Voltage Fast-Acting Ceramic Tube Fuse

    Eaton AHC-6-R 6 A 600 Vac High Voltage Fast-Acting Ceramic Tube Fuse belongs to the Eaton range. It carries 6 A, rated 600 Vac / 600 Vdc, uses a fast-acting element, in a ceramic body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / AHC Series
    Part numberAHC-6-R
    Current rating6 A
    Voltage rating600 Vac / 600 Vdc
    Interrupting rating (AC)10,000 A @ 600 Vac
    Interrupting rating (DC)10,000 A @ 600 Vdc
    Typical resistance30.3 mΩ
    Typical voltage drop250 mV @ rated current
    Package1/4 x 1-1/4 in (6.3 x 32 mm) ceramic tube, cartridge or axial lead
    Agency / environmentalcURus recognition file E19180, guide JDYX2 and JDYX8; RoHS compliant and halogen free

    Design Notes

    • Interrupting capability is 10,000 A @ 600 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 600 Vac / 600 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 6 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV
    • transformer

    Ordering Details

    Order code AHC-6-R from Eaton, supplied in 1/4 x 1-1/4 in (6.3 x 32 mm) ceramic tube, cartridge or axial lead. Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the AHC-6-R?

    6 A continuous at 600 Vac / 600 Vdc, interrupting rating 10,000 A @ 600 Vac.

    Is the AHC-6-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the AHC-6-R be used on a higher fault-current circuit?

    No — its interrupting rating is 10,000 A @ 600 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.