Eaton AK1-430C TVS Diode
Eaton AK1-430C TVS Diode

Eaton AK1-430C TVS Diode

Share
AK1-430C: transient voltage suppressor diode, 430 V standoff, 625 V clamp, 1000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK1-430C TVS Diode

    AK1-430C at a glance: transient voltage suppressor diode, 430 V standoff, 625 V clamp, 1000 A pulse, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberAK1-430C
    Standoff voltage (VR)430 V
    Leakage current at VR10 uA
    Breakdown voltage at IT440 V to 490 V
    Test current (IT)10 mA
    Clamping voltage at IPP625 V
    Peak pulse current1000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11208

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11208; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 11.36 percent, from 440 V to 490 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 430 V standing the leakage is at most 10 uA, so the part draws 4.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK1 family this is item 3 of 3 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.