AK10-015C: transient voltage suppressor diode, 15 V standoff, 28 V clamp, 10000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK10-015C TVS Diode

    AK10-015C at a glance: transient voltage suppressor diode, 15 V standoff, 28 V clamp, 10000 A pulse, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberAK10-015C
    Standoff voltage (VR)15 V
    Leakage current at VR10 uA
    Breakdown voltage at IT16 V to 19 V
    Test current (IT)10 mA
    Clamping voltage at IPP28 V
    Peak pulse current10000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11210

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11210; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 18.75 percent, from 16 V to 19 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 15 V standing the leakage is at most 10 uA, so the part draws 0.15 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK10 family this is item 1 of 18 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.