| Parameter | Value |
|---|---|
| Orderable part number | AK10-066C |
| Standoff voltage (VR) | 66 V |
| Leakage current at VR | 10 uA |
| Breakdown voltage at IT | 72 V to 80 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 120 V |
| Peak pulse current | 10000 A |
| Polarity | Bidirectional |
| Package | Axial leaded |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11210 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11210; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 11.11 percent, from 72 V to 80 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 66 V standing the leakage is at most 10 uA, so the part draws 0.66 mW on the rail. Small, but it is the number that matters on a battery input.
Within the AK10 family this is item 7 of 18 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.