| Parameter | Value |
|---|---|
| Orderable part number | AK10-076C |
| Standoff voltage (VR) | 76 V |
| Leakage current at VR | 10 uA |
| Breakdown voltage at IT | 85 V to 95 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 140 V |
| Peak pulse current | 10000 A |
| Polarity | Bidirectional |
| Package | Axial leaded |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11210 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11210; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 11.76 percent, from 85 V to 95 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 76 V standing the leakage is at most 10 uA, so the part draws 0.76 mW on the rail. Small, but it is the number that matters on a battery input.
Within the AK10 family this is item 8 of 18 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.