Eaton AK10-240C TVS Diode
Eaton AK10-240C TVS Diode

Eaton AK10-240C TVS Diode

Share
AK10-240C: transient voltage suppressor diode, 240 V standoff, 340 V clamp, 10000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK10-240C TVS Diode

    AK10-240C at a glance: transient voltage suppressor diode, 240 V standoff, 340 V clamp, 10000 A pulse, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberAK10-240C
    Standoff voltage (VR)240 V
    Leakage current at VR10 uA
    Breakdown voltage at IT250 V to 285 V
    Test current (IT)10 mA
    Clamping voltage at IPP340 V
    Peak pulse current10000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11210

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11210; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 14 percent, from 250 V to 285 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 240 V standing the leakage is at most 10 uA, so the part draws 2.4 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK10 family this is item 14 of 18 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.