Eaton AK10-300C TVS Diode
Eaton AK10-300C TVS Diode

Eaton AK10-300C TVS Diode

Share
AK10-300C: transient voltage suppressor diode, 300 V standoff, 470 V clamp, 10000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK10-300C TVS Diode

    AK10-300C at a glance: transient voltage suppressor diode, 300 V standoff, 470 V clamp, 10000 A pulse, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberAK10-300C
    Standoff voltage (VR)300 V
    Leakage current at VR10 uA
    Breakdown voltage at IT330 V to 366 V
    Test current (IT)10 mA
    Clamping voltage at IPP470 V
    Peak pulse current10000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11210

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11210; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.91 percent, from 330 V to 366 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 300 V standing the leakage is at most 10 uA, so the part draws 3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK10 family this is item 16 of 18 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products