AK10-380C: transient voltage suppressor diode, 380 V standoff, 520 V clamp, 10000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK10-380C TVS Diode

    AK10-380C at a glance: transient voltage suppressor diode, 380 V standoff, 520 V clamp, 10000 A pulse, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberAK10-380C
    Standoff voltage (VR)380 V
    Leakage current at VR10 uA
    Breakdown voltage at IT401 V to 443 V
    Test current (IT)10 mA
    Clamping voltage at IPP520 V
    Peak pulse current10000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11210

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11210; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.47 percent, from 401 V to 443 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 380 V standing the leakage is at most 10 uA, so the part draws 3.8 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK10 family this is item 17 of 18 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.