AK6-020C: transient voltage suppressor diode, 20 V standoff, 50 V clamp, 6000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK6-020C TVS Diode

    AK6-020C at a glance: transient voltage suppressor diode, 20 V standoff, 50 V clamp, 6000 A pulse, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberAK6-020C
    Standoff voltage (VR)20 V
    Leakage current at VR10 uA
    Breakdown voltage at IT22 V to 24 V
    Test current (IT)10 mA
    Clamping voltage at IPP50 V
    Peak pulse current6000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11209

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11209; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 9.091 percent, from 22 V to 24 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 10 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK6 family this is item 2 of 17 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.