AK6-300C: transient voltage suppressor diode, 300 V standoff, 470 V clamp, 6000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK6-300C TVS Diode

    AK6-300C at a glance: transient voltage suppressor diode, 300 V standoff, 470 V clamp, 6000 A pulse, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberAK6-300C
    Standoff voltage (VR)300 V
    Leakage current at VR10 uA
    Breakdown voltage at IT330 V to 366 V
    Test current (IT)10 mA
    Clamping voltage at IPP470 V
    Peak pulse current6000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11209

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11209; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.91 percent, from 330 V to 366 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 300 V standing the leakage is at most 10 uA, so the part draws 3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK6 family this is item 15 of 17 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.