Eaton AK6-430C TVS Diode
Eaton AK6-430C TVS Diode

Eaton AK6-430C TVS Diode

Share
AK6-430C: transient voltage suppressor diode, 430 V standoff, 625 V clamp, 6000 A pulse, bidirectional.
    • Product Details
    • Download

    Eaton AK6-430C TVS Diode

    AK6-430C at a glance: transient voltage suppressor diode, 430 V standoff, 625 V clamp, 6000 A pulse, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberAK6-430C
    Standoff voltage (VR)430 V
    Leakage current at VR10 uA
    Breakdown voltage at IT440 V to 490 V
    Test current (IT)10 mA
    Clamping voltage at IPP625 V
    Peak pulse current6000 A
    PolarityBidirectional
    PackageAxial leaded
    MountingThrough-hole
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11209

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11209; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 11.36 percent, from 440 V to 490 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 430 V standing the leakage is at most 10 uA, so the part draws 4.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the AK6 family this is item 17 of 17 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.