AMLV04V05C090: multilayer varistor ESD suppressor, 8.8-13.2 V varistor voltage, 5.5 V working, 30 V clamp, 90 pF, 0.05 J.
    • Product Details
    • Download

    Eaton AMLV04V05C090 MLV ESD Suppressor 90 pF

    AMLV04V05C090 at a glance: multilayer varistor ESD suppressor, 8.8-13.2 V varistor voltage, 5.5 V working, 30 V clamp, 90 pF, 0.05 J.

    Key Specifications

    ParameterValue
    Orderable part numberAMLV04V05C090
    Working voltage, DC5.5 Vdc
    Working voltage, AC4 Vac
    Varistor voltage at 1 mA8.8 V to 13.2 V
    Clamping voltage at 1 A30 V
    Energy absorption, 10/1000 us0.05 J
    Peak current, 8/20 us10 A
    Typical capacitance at 1 MHz90 pF
    Leakage current at working voltagemax. 20 uA
    Package0402 (1005 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1078

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.

    The clamp column works out at 2.73 times the varistor voltage: 30 V at the rated current against 11 V at 1 mA. That ratio is what the downstream part has to survive, not the 11 V figure on the label.

    Standing at 5.5 V the leakage is at most 20 uA, which is 0.11 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.

    The 90 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the AMLV family this is item 2 of 28 in the Eaton catalogue.

    What This Family Is For

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.