AMLV08V26C500: multilayer varistor ESD suppressor, 29.7-36.3 V varistor voltage, 26 V working, 56 V clamp, 500 pF, 0.3 J.
    • Product Details
    • Download

    Eaton AMLV08V26C500 0805 Chip Varistor 26 Vdc

    AMLV08V26C500 at a glance: multilayer varistor ESD suppressor, 29.7-36.3 V varistor voltage, 26 V working, 56 V clamp, 500 pF, 0.3 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberAMLV08V26C500
    Working voltage, DC26 Vdc
    Working voltage, AC20 Vac
    Varistor voltage at 1 mA29.7 V to 36.3 V
    Clamping voltage at 1 A56 V
    Energy absorption, 10/1000 us0.3 J
    Peak current, 8/20 us80 A
    Typical capacitance at 1 MHz500 pF
    Vjump (5 min)27 V
    WLD (10 pulses)1 J
    Leakage current at working voltagemax. 20 uA
    Package0805 (2012 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1078

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 1.7 times the varistor voltage: 56 V at the rated current against 33 V at 1 mA. That ratio is what the downstream part has to survive, not the 33 V figure on the label.

    Standing at 26 V the leakage is at most 20 uA, which is 0.52 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.

    The 500 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the AMLV family this is item 11 of 28 in the Eaton catalogue.

    Series Positioning

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.