Eaton AMLV12V48C270 Multilayer Varistor, 100 V Clamp
Eaton AMLV12V48C270 Multilayer Varistor, 100 V Clamp

Eaton AMLV12V48C270 Multilayer Varistor, 100 V Clamp

Share
AMLV12V48C270: multilayer varistor ESD suppressor, 55.8-68.2 V varistor voltage, 48 V working, 100 V clamp, 270 pF, 0.4 J.
    • Product Details
    • Download

    Eaton AMLV12V48C270 Multilayer Varistor, 100 V Clamp

    AMLV12V48C270 at a glance: multilayer varistor ESD suppressor, 55.8-68.2 V varistor voltage, 48 V working, 100 V clamp, 270 pF, 0.4 J.

    Specification Table

    ParameterValue
    Orderable part numberAMLV12V48C270
    Working voltage, DC48 Vdc
    Working voltage, AC37 Vac
    Varistor voltage at 1 mA55.8 V to 68.2 V
    Clamping voltage at 1 A100 V
    Energy absorption, 10/1000 us0.4 J
    Peak current, 8/20 us100 A
    Typical capacitance at 1 MHz270 pF
    Vjump (5 min)59 V
    WLD (10 pulses)1.2 J
    Leakage current at working voltagemax. 20 uA
    Package1206 (3216 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1078

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.

    The clamp column works out at 1.61 times the varistor voltage: 100 V at the rated current against 62 V at 1 mA. That ratio is what the downstream part has to survive, not the 62 V figure on the label.

    Standing at 48 V the leakage is at most 20 uA, which is 0.96 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.

    The 270 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the AMLV family this is item 16 of 28 in the Eaton catalogue.

    Positioning in the Range

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products