Eaton C308F125mA 125 mA 250 Vac/dc Ceramic Tube Fuse
Eaton C308F125mA 125 mA 250 Vac/dc Ceramic Tube Fuse

Eaton C308F125mA 125 mA 250 Vac/dc Ceramic Tube Fuse

Share
pEaton C308F125mA — 125 mA, 250 V, ceramic cartridge fuse, 4000 A @ 250 Vac/dc interrupting./p
    • Product Details
    • Download

    Eaton C308F125mA 125 mA 250 Vac/dc Ceramic Tube Fuse

    The C308F125mA from Eaton carries 125 mA, rated 250 Vac / 250 Vdc, in a ceramic body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / C308F Series
    Orderable part numberC308F125mA
    Ferrule part numberC308F125mA
    Axial lead equivalentC308F-V-125mA
    Current rating125 mA
    Voltage rating250 Vac / 250 Vdc
    Interrupting rating4000 A @ 250 Vac/dc
    Typical DC cold resistance2.20 Ohm
    Typical melting I2t0.00134 A2s (measured at 10 In)
    Colour codingOrange
    Package3 x 8.4 mm ceramic tube, silver-plated brass end caps, optional axial leads
    Operating temperature-55 C to +125 C with derating
    Agency / environmentalcURus recognition file E19180, guide JDYX2 / JDYX8; electrical performance to EN 60079-11 for intrinsically safe applications; RoHS compliant

    Practical Notes

    • Interrupting capability is 4000 A @ 250 Vac/dc — confirm the circuit's prospective fault current stays below this.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 250 Vac / 250 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 125 mA to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • transformer

    Buying Notes

    Order code C308F125mA from Eaton, supplied in 3 x 8.4 mm ceramic tube, silver-plated brass end caps, optional axial leads. Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the C308F125mA?

    125 mA continuous at 250 Vac / 250 Vdc, interrupting rating 4000 A @ 250 Vac/dc.

    Can the C308F125mA be used on a higher fault-current circuit?

    No — its interrupting rating is 4000 A @ 250 Vac/dc. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message