Eaton C518-3-R 3 A 250 Vac Fast-Acting Axial Glass Fuse
Eaton C518-3-R 3 A 250 Vac Fast-Acting Axial Glass Fuse

Eaton C518-3-R 3 A 250 Vac Fast-Acting Axial Glass Fuse

Share
pEaton C518-3-R — 3 A, 250 V, fast-acting glass cartridge fuse, 100 A interrupting./p
    • Product Details
    • Download

    Eaton C518-3-R 3 A 250 Vac Fast-Acting Axial Glass Fuse

    Built by Eaton, the C518-3-R carries 3 A, rated 250 Vac, uses a fast-acting element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / C518 Series
    Orderable part numberC518-3-R (reel code TR2/C518-3-R)
    Current rating3 A
    Voltage rating250 Vac
    Interrupting rating @ 250 Vac100 A
    Interrupting rating @ 125 Vac10,000 A
    Typical DC cold resistance0.038 Ohm
    Typical melting I2t6.1 A2s
    Typical voltage drop116 mV
    Package5 x 15 mm glass tube, nickel-plated brass end caps, axial leads, optional fluoropolymer sleeve
    Option codeS = insulation sleeve (flexible fluoropolymer, UL VW-1)
    Agency / environmentalUL Recognition guide JDYX2 file E19180; UL Listed to UL 248-14; CSA certification class 1422-01 file 53787; RoHS compliant

    Selection Notes

    • Interrupting capability is 100 A — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 3 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV
    • lighting
    • LED driver

    Part Number and Packing

    Order code C518-3-R from Eaton, supplied in 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads, optional fluoropolymer sleeve. Confirm the exact suffix before release.

    Q&A

    What are the ratings of the C518-3-R?

    3 A continuous at 250 Vac, interrupting rating 100 A.

    Is the C518-3-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the C518-3-R be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A. Choose a part whose breaking capacity exceeds the prospective fault current.