| Parameter | Rating |
|---|---|
| Parameter | Value |
| Manufacturer / Series | Eaton / C518 Series |
| Orderable part number | C518-5-R (reel code TR2/C518-5-R) |
| Current rating | 5 A |
| Voltage rating | 250 Vac |
| Interrupting rating @ 250 Vac | 200 A |
| Interrupting rating @ 125 Vac | 10,000 A |
| Typical DC cold resistance | 0.018 Ohm |
| Typical melting I2t | 22.4 A2s |
| Typical voltage drop | 91 mV |
| Package | 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads, optional fluoropolymer sleeve |
| Option code | S = insulation sleeve (flexible fluoropolymer, UL VW-1) |
| Agency / environmental | UL Recognition guide JDYX2 file E19180; UL Listed to UL 248-14; CSA certification class 1422-01 file 53787; RoHS compliant |
Common installation contexts include:
Order code C518-5-R from Eaton, supplied in 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads, optional fluoropolymer sleeve. Confirm the exact suffix before release.
What are the ratings of the C518-5-R?
5 A continuous at 250 Vac, interrupting rating 200 A.
Is the C518-5-R fast-acting or time-delay?
It is fast-acting. Expect it to open quickly on overload.
Can the C518-5-R be used on a higher fault-current circuit?
No — its interrupting rating is 200 A. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd