
| Parameter | Rating |
|---|---|
| Parameter | Value |
| Manufacturer / Series | Eaton / C519 Series |
| Orderable part number | C519-125-R (carton codes BK-C519-125-R / BK1-C519-125-R) |
| Current rating | 0.125 A |
| Voltage rating | 250 Vac |
| Interrupting rating @ 600 Vac | not rated |
| Interrupting rating @ 250 Vac | 35 A |
| Interrupting rating @ 125 Vac | 10,000 A |
| Typical DC cold resistance | 4.72 Ohm |
| Typical melting I2t | 0.101 A2s |
| Maximum voltage drop | 770 mV |
| Package | 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads |
| Agency / environmental | cULus Listed guide JDYX / JDYX7 file E19180 (125 mA - 3 A); cURus Recognized guide JDYX2 / JDYX8 file E19180 (350 mA, 3.5 A - 7 A). Philippines-manufactured parts carry only these two approvals; RoHS compliant |
Common installation contexts include:
Order code C519-125-R from Eaton, supplied in 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads. Confirm the exact suffix before release.
What are the ratings of the C519-125-R?
0.125 A continuous at 250 Vac, interrupting rating not rated.
Is the C519-125-R fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the C519-125-R be used on a higher fault-current circuit?
No — its interrupting rating is not rated. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd