Eaton C519-4-R 4 A 125 Vac Time-Delay Glass Fuse
Eaton C519-4-R 4 A 125 Vac Time-Delay Glass Fuse

Eaton C519-4-R 4 A 125 Vac Time-Delay Glass Fuse

Share
pEaton C519-4-R — 4 A, 125 V, time-delay glass cartridge fuse, not rated interrupting./p
    • Product Details
    • Download

    Eaton C519-4-R 4 A 125 Vac Time-Delay Glass Fuse

    Built by Eaton, the C519-4-R carries 4 A, rated 125 Vac, uses a time-delay element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / C519 Series
    Orderable part numberC519-4-R (carton codes BK-C519-4-R / BK1-C519-4-R)
    Current rating4 A
    Voltage rating125 Vac
    Interrupting rating @ 600 Vacnot rated
    Interrupting rating @ 250 Vacnot rated
    Interrupting rating @ 125 Vac400 A
    Typical DC cold resistance0.023 Ohm
    Typical melting I2t233.346 A2s
    Maximum voltage drop130 mV
    Package5 x 15 mm glass tube, nickel-plated brass end caps, axial leads
    Agency / environmentalcULus Listed guide JDYX / JDYX7 file E19180 (125 mA - 3 A); cURus Recognized guide JDYX2 / JDYX8 file E19180 (350 mA, 3.5 A - 7 A). Philippines-manufactured parts carry only these two approvals; RoHS compliant

    Selection Notes

    • Interrupting capability is not rated — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 125 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 4 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • lighting
    • LED driver

    Part Number and Packing

    Order code C519-4-R from Eaton, supplied in 5 x 15 mm glass tube, nickel-plated brass end caps, axial leads. Confirm the exact suffix before release.

    Q&A

    What are the ratings of the C519-4-R?

    4 A continuous at 125 Vac, interrupting rating not rated.

    Is the C519-4-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the C519-4-R be used on a higher fault-current circuit?

    No — its interrupting rating is not rated. Choose a part whose breaking capacity exceeds the prospective fault current.