Eaton C520-500-R 500 mA 250 Vac Fast-Acting Glass Fuse
Eaton C520-500-R 500 mA 250 Vac Fast-Acting Glass Fuse

Eaton C520-500-R 500 mA 250 Vac Fast-Acting Glass Fuse

Share
pEaton C520-500-R — 500 mA, 250 V, fast-acting glass cartridge fuse, 35 A interrupting./p
    • Product Details
    • Download

    Eaton C520-500-R 500 mA 250 Vac Fast-Acting Glass Fuse

    Built by Eaton, the C520-500-R carries 0.5 A, rated 250 Vac, uses a fast-acting element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / C520 Series
    Orderable part numberC520-500-R (carton codes BK-C520-500-R / BK1-C520-500-R)
    Current rating0.5 A
    Voltage rating250 Vac
    Interrupting rating @ 250 Vac35 A
    Interrupting rating @ 125 Vac10,000 A
    Typical DC cold resistance1.66 Ohm
    Typical melting I2t0.059 A2s
    Typical voltage drop845 mV
    Package5 x 14.48 mm glass tube (5 x 15 mm nominal), nickel-plated brass end caps
    Body length14.48 mm (nominal 5 x 15 mm class)
    Agency / environmentalUL Listed guide JDYX file E19180; CSA certification class 1422-01 file 53787; UL Listed to UL 248-14; RoHS compliant

    Selection Notes

    • Interrupting capability is 35 A — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 0.5 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • transformer

    Part Number and Packing

    Order code C520-500-R from Eaton, supplied in 5 x 14.48 mm glass tube (5 x 15 mm nominal), nickel-plated brass end caps. Confirm the exact suffix before release.

    Q&A

    What are the ratings of the C520-500-R?

    0.5 A continuous at 250 Vac, interrupting rating 35 A.

    Is the C520-500-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the C520-500-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message