    Eaton CB61F40A 40 A 63 Vdc Fast-Acting Brick Fuse belongs to the Eaton range. It carries 40 A, rated no AC rating, uses a fast-acting element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / CB61F Series
    Orderable part numberCB61F40A (add -TR1 or -TR2 packaging suffix)
    Current rating40 A
    Voltage rating (AC)no AC rating
    Voltage rating (DC)63 Vdc
    Interrupting rating (AC)not rated for AC
    Interrupting rating (DC)500 A @ 63 Vdc
    Typical DC cold resistance0.9 mOhm
    Typical melting I2t1600 A2s
    Typical voltage drop50 mV
    Part marking40
    Package2410 (6125 metric) surface mount brick, wire-in-air element
    Moisture sensitivity levelMSL 1
    Agency / environmentalUL Listed cULus file E19180 guide JDYX (2-15 A); UL Recognized cURus file E19180 guide JDYX2 (20-40 A); CQC CQC09012040316 (2-6.3 A and 8-10 A); designed to UL 248; RoHS compliant and halogen free

    Design Notes

    • Interrupting capability is not rated for AC — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Working voltage must stay at or below no AC rating; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 40 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV

    Ordering Details

    Order code CB61F40A from Eaton, supplied in 2410 (6125 metric) surface mount brick, wire-in-air element. Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the CB61F40A?

    40 A continuous at no AC rating, interrupting rating not rated for AC.

    Is the CB61F40A fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the CB61F40A be used on a higher fault-current circuit?

    No — its interrupting rating is not rated for AC. Choose a part whose breaking capacity exceeds the prospective fault current.