Eaton CB61F5A 5 A 125 Vac/Vdc Fast-Acting Brick Fuse
Eaton CB61F5A 5 A 125 Vac/Vdc Fast-Acting Brick Fuse

Eaton CB61F5A 5 A 125 Vac/Vdc Fast-Acting Brick Fuse

Share
pEaton CB61F5A — 5 A, 125 V, fast-acting fuse, 100 A @ 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton CB61F5A 5 A 125 Vac/Vdc Fast-Acting Brick Fuse

    Eaton CB61F5A 5 A 125 Vac/Vdc Fast-Acting Brick Fuse belongs to the Eaton range. It carries 5 A, rated 125 Vac, uses a fast-acting element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesEaton / CB61F Series
    Orderable part numberCB61F5A (add -TR1 or -TR2 packaging suffix)
    Current rating5 A
    Voltage rating (AC)125 Vac
    Voltage rating (DC)125 Vdc
    Interrupting rating (AC)100 A @ 125 Vac
    Interrupting rating (DC)300 A @ 125 Vdc
    Typical DC cold resistance13 mOhm
    Typical melting I2t7.7 A2s
    Typical voltage drop90 mV
    Part marking5
    Package2410 (6125 metric) surface mount brick, wire-in-air element
    Moisture sensitivity levelMSL 1
    Agency / environmentalUL Listed cULus file E19180 guide JDYX (2-15 A); UL Recognized cURus file E19180 guide JDYX2 (20-40 A); CQC CQC09012040316 (2-6.3 A and 8-10 A); designed to UL 248; RoHS compliant and halogen free

    Design Notes

    • Interrupting capability is 100 A @ 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Working voltage must stay at or below 125 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 5 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV
    • lighting
    • LED driver

    Ordering Details

    Order code CB61F5A from Eaton, supplied in 2410 (6125 metric) surface mount brick, wire-in-air element. Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the CB61F5A?

    5 A continuous at 125 Vac, interrupting rating 100 A @ 125 Vac.

    Is the CB61F5A fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the CB61F5A be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A @ 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message