Eaton CLA1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated
Eaton CLA1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

Eaton CLA1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

Share
Eaton CLA1108-2-50TR-R: 2-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CLA1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

    CLA1108-2-50TR-R: 2-phase power inductor, OCL 380 nH / 380 nH (per pin pair), DCR 0.28 mOhm, 50 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCLA1108-2-50TR-R
    Rated inductance per phase50 nH ±20%
    Number of phases2
    Open circuit inductance (OCL)380 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCLA1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The 50 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.28 mOhm at 20 °C is the number that sets efficiency. At 50 A per phase the winding loss is 0.7 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Series Positioning

    CLA1108 是 CL1108 的降噪版本,同样的电气参数,结构上针对啸叫做了优化。

    • Typical use: 对啸叫敏感的服务器与工控设备.
    • CLA 与 CL 的引脚定义和电气参数一致,但磁性材料与结构不同,不能随意互换——尤其不能把 CLA 换成 CL 后再沿用原来的噪声评估。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.