Eaton CLA1108-3-50TR-R 3-Phase Multi-Phase Power Inductor, 50 nH per phase
Eaton CLA1108-3-50TR-R 3-Phase Multi-Phase Power Inductor, 50 nH per phase

Eaton CLA1108-3-50TR-R 3-Phase Multi-Phase Power Inductor, 50 nH per phase

Share
Eaton CLA1108-3-50TR-R: 3-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CLA1108-3-50TR-R 3-Phase Multi-Phase Power Inductor, 50 nH per phase

    CLA1108-3-50TR-R at a glance: 3-phase multi-phase power inductor, 0.28 mOhm DCR, 50 A rated current per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCLA1108-3-50TR-R
    Number of phases3
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)400 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCLA1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The 50 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.28 mOhm is why the 3-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Series Positioning

    CLA1108 是 CL1108 的降噪版本,同样的电气参数,结构上针对啸叫做了优化。

    • Typical use: 对啸叫敏感的服务器与工控设备.
    • CLA 与 CL 的引脚定义和电气参数一致,但磁性材料与结构不同,不能随意互换——尤其不能把 CLA 换成 CL 后再沿用原来的噪声评估。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. 3 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 3-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.