Eaton CLA1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase
Eaton CLA1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Eaton CLA1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Share
Eaton CLA1108-4-50TR-R: 4-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CLA1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

    CLA1108-4-50TR-R at a glance: 4-phase multi-phase power inductor, 0.28 mOhm DCR, 50 A rated current per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCLA1108-4-50TR-R
    Rated inductance per phase50 nH ±20%
    Number of phases4
    Open circuit inductance (OCL)400 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCLA1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The 50 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.28 mOhm is why the 4-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Where This Series Fits

    CLA1108 是 CL1108 的降噪版本,同样的电气参数,结构上针对啸叫做了优化。

    • Typical use: 对啸叫敏感的服务器与工控设备.
    • CLA 与 CL 的引脚定义和电气参数一致,但磁性材料与结构不同,不能随意互换——尤其不能把 CLA 换成 CL 后再沿用原来的噪声评估。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd