Eaton CLB1108-3-50TR-R: 3-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 25 A rated per phase.
    • Product Details
    • Download

    Eaton CLB1108-3-50TR-R 3-Phase Multi-Phase Power Inductor, 50 nH per phase

    CLB1108-3-50TR-R: 3-phase power inductor, OCL 200 nH at 0 Adc, 150 nH at 25 A, 100 nH at 23 A, DCR 0.28 mOhm, 25 A per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCLB1108-3-50TR-R
    Number of phases3
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)200 nH at 0 Adc, 150 nH at 25 A, 100 nH at 23 A
    DC resistance (DCR)0.28 mOhm
    Rated current per phase25 A
    Peak current per phase110 A
    PackageCLB1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 3 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    DCR 0.28 mOhm is why the 3-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Where This Series Fits

    CLB1108 是 50 nH 多相电感,给出 OCL 在 Isat1 与 Isat2 两个偏置点的值。

    • Typical use: 多相 VRM、高频大电流供电.
    • CLB 的 OCL 随偏置下降得比标准件慢(150 nH @25 A),这是它相对同尺寸其它系列的核心差别。
    • Data sheet Volterra; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. 3 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 3-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-clb1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.