Eaton CMS1-13-R Common-Mode Noise Suppressor, 166 uH
Eaton CMS1-13-R Common-Mode Noise Suppressor, 166 uH

Eaton CMS1-13-R Common-Mode Noise Suppressor, 166 uH

Share
Eaton CMS1-13-R: 166 uH common-mode inductor, 1 A Irms, 0.138 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS1-13-R Common-Mode Noise Suppressor, 166 uH

    CMS1-13-R at a glance: 166 uH common-mode inductor, 1 A Irms, 0.138 ohm DCR, surface mount.

    Product Specifications

    ParameterValue
    Orderable part numberCMS1-13-R
    Open circuit inductance (OCL)166 uH minimum, (1-2) & (4-3)
    I rms (max)1 A
    DCR typical @ 20 °C (1-2)0.138 ohm
    DCR typical @ 20 °C (4-3)0.138 ohm
    Leakage inductance typ1.83 uH
    Interwinding capacitance typ3.1 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.

    Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 166 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 1 A Irms rating is not the thing limiting the design.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 1 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.138 ohm of DCR the winding loss at that current is 0.14 W. CMS1 is the smallest of the three CMS footprints

    Frequently Asked Questions

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.