Eaton CMS1-14-R Common-Mode Inductor, 205 uH OCL
Eaton CMS1-14-R Common-Mode Inductor, 205 uH OCL

Eaton CMS1-14-R Common-Mode Inductor, 205 uH OCL

Share
Eaton CMS1-14-R: 205 uH common-mode inductor, 0.85 A Irms, 0.186 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS1-14-R Common-Mode Inductor, 205 uH OCL

    CMS1-14-R: common-mode choke, OCL 205 uH minimum, 0.85 A Irms, leakage 2.25 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS1-14-R
    I rms (max)0.85 A
    Open circuit inductance (OCL)205 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.186 ohm
    DCR typical @ 20 °C (4-3)0.186 ohm
    Leakage inductance typ2.25 uH
    Interwinding capacitance typ3.2 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.

    Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 205 uH is a high-inductance part with a correspondingly low 0.85 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    The 205 uH of common-mode inductance is what blocks the noise; the 2.25 uH of leakage inductance is what gets past, and the 3.2 pF of interwinding capacitance is what couples across the windings at high frequency. CMS1 is the smallest of the three CMS footprints

    Frequently Asked Questions

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.