| Parameter | Value |
|---|---|
| Orderable part number | CMS2-14-R |
| Open circuit inductance (OCL) | 1340 uH minimum, (1-2) & (4-3) |
| I rms (max) | 0.5 A |
| DCR typical @ 20 °C (1-2) | 0.62 ohm |
| DCR typical @ 20 °C (4-3) | 0.62 ohm |
| Leakage inductance typ | 9 uH |
| Interwinding capacitance typ | 5.4 pF |
| Package | CMS series, surface mount |
| Operating temperature | 160 °C maximum |
| RoHS | Compliant (-R suffix) |
A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.
Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 1340 uH is a high-inductance part with a correspondingly low 0.5 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.
CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。
Irms 0.5 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.62 ohm of DCR the winding loss at that current is 0.15 W. CMS2 is the mid-size CMS footprint
What impedance should I pick?
The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.
What impedance should I pick?
The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.
Can I put it on a power line?
Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.
Design note: pick the choke by impedance at the noise
frequency, then confirm DCR and rated current against the signal or the rail.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd