Eaton CMS2-3-R Common-Mode Inductor, 57 uH OCL
Eaton CMS2-3-R Common-Mode Inductor, 57 uH OCL

Eaton CMS2-3-R Common-Mode Inductor, 57 uH OCL

Share
Eaton CMS2-3-R: 57 uH common-mode inductor, 3.6 A Irms, 0.012 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS2-3-R Common-Mode Inductor, 57 uH OCL

    CMS2-3-R: common-mode choke, OCL 57 uH minimum, 3.6 A Irms, leakage 0.47 uH.

    Product Specifications

    ParameterValue
    Orderable part numberCMS2-3-R
    Open circuit inductance (OCL)57 uH minimum, (1-2) & (4-3)
    I rms (max)3.6 A
    DCR typical @ 20 °C (1-2)0.012 ohm
    DCR typical @ 20 °C (4-3)0.012 ohm
    Leakage inductance typ0.47 uH
    Interwinding capacitance typ2.5 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The impedance figure is measured across the winding pair, which is exactly the common-mode path. That is why these parts are picked by impedance at the noise frequency rather than by inductance.

    For a DC-DC output filter this is the part that decides whether the noise stays inside the conducted limits, and how much margin the design keeps at the top of the load step. 57 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 3.6 A Irms rating is not the thing limiting the design.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    The 57 uH of common-mode inductance is what blocks the noise; the 0.47 uH of leakage inductance is what gets past, and the 2.5 pF of interwinding capacitance is what couples across the windings at high frequency. CMS2 is the mid-size CMS footprint

    Frequently Asked Questions

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Why are there two DCR values?
    The CMS series specifies each winding separately, measured between (1-2) and between (4-3).

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.