Eaton CMS2-9-R - 460 uH Common-Mode Inductor
Eaton CMS2-9-R - 460 uH Common-Mode Inductor

Eaton CMS2-9-R - 460 uH Common-Mode Inductor

Share
Eaton CMS2-9-R: 460 uH common-mode inductor, 1.1 A Irms, 0.12 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS2-9-R - 460 uH Common-Mode Inductor

    CMS2-9-R at a glance: 460 uH common-mode inductor, 1.1 A Irms, 0.12 ohm DCR, surface mount.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS2-9-R
    I rms (max)1.1 A
    Open circuit inductance (OCL)460 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.12 ohm
    DCR typical @ 20 °C (4-3)0.12 ohm
    Leakage inductance typ3.3 uH
    Interwinding capacitance typ4.3 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The impedance figure is measured across the winding pair, which is exactly the common-mode path. That is why these parts are picked by impedance at the noise frequency rather than by inductance.

    For a DC-DC output filter this is the part that decides whether the noise stays inside the conducted limits, and how much margin the design keeps at the top of the load step. 460 uH is a high-inductance part with a correspondingly low 1.1 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    The 460 uH of common-mode inductance is what blocks the noise; the 3.3 uH of leakage inductance is what gets past, and the 4.3 pF of interwinding capacitance is what couples across the windings at high frequency. CMS2 is the mid-size CMS footprint

    Frequently Asked Questions

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Why are there two DCR values?
    The CMS series specifies each winding separately, measured between (1-2) and between (4-3).

    Why are there two DCR values?
    The CMS series specifies each winding separately, measured between (1-2) and between (4-3).

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.