Eaton CMS3-10-R Surface-Mount Common-Mode Choke 518 uH
Eaton CMS3-10-R Surface-Mount Common-Mode Choke 518 uH

Eaton CMS3-10-R Surface-Mount Common-Mode Choke 518 uH

Share
Eaton CMS3-10-R: 518 uH common-mode inductor, 1.45 A Irms, 0.076 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS3-10-R Surface-Mount Common-Mode Choke 518 uH

    CMS3-10-R: common-mode choke, OCL 518 uH minimum, 1.45 A Irms, leakage 4.2 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS3-10-R
    Open circuit inductance (OCL)518 uH minimum, (1-2) & (4-3)
    I rms (max)1.45 A
    DCR typical @ 20 °C (1-2)0.076 ohm
    DCR typical @ 20 °C (4-3)0.076 ohm
    Leakage inductance typ4.2 uH
    Interwinding capacitance typ4.85 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.

    Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 518 uH is a high-inductance part with a correspondingly low 1.45 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 1.45 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.076 ohm of DCR the winding loss at that current is 0.16 W. CMS3 is the largest CMS footprint, with the lowest DCR of the three

    Frequently Asked Questions

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd