Eaton CMS3-14-R Surface-Mount Common-Mode Choke 1310 uH
Eaton CMS3-14-R Surface-Mount Common-Mode Choke 1310 uH

Eaton CMS3-14-R Surface-Mount Common-Mode Choke 1310 uH

Share
Eaton CMS3-14-R: 1310 uH common-mode inductor, 0.75 A Irms, 0.3 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS3-14-R Surface-Mount Common-Mode Choke 1310 uH

    CMS3-14-R at a glance: 1310 uH common-mode inductor, 0.75 A Irms, 0.3 ohm DCR, surface mount.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS3-14-R
    I rms (max)0.75 A
    Open circuit inductance (OCL)1310 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.3 ohm
    DCR typical @ 20 °C (4-3)0.3 ohm
    Leakage inductance typ9.6 uH
    Interwinding capacitance typ5.8 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.

    Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 1310 uH is a high-inductance part with a correspondingly low 0.75 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    The 1310 uH of common-mode inductance is what blocks the noise; the 9.6 uH of leakage inductance is what gets past, and the 5.8 pF of interwinding capacitance is what couples across the windings at high frequency. CMS3 is the largest CMS footprint, with the lowest DCR of the three

    Frequently Asked Questions

    Why are there two DCR values?
    The CMS series specifies each winding separately, measured between (1-2) and between (4-3).

    What impedance should I pick?
    The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products