| Parameter | Value |
|---|---|
| Orderable part number | CMS3-4-R |
| Open circuit inductance (OCL) | 88 uH minimum, (1-2) & (4-3) |
| I rms (max) | 3.95 A |
| DCR typical @ 20 °C (1-2) | 0.01 ohm |
| DCR typical @ 20 °C (4-3) | 0.01 ohm |
| Leakage inductance typ | 0.85 uH |
| Interwinding capacitance typ | 3.5 pF |
| Package | CMS series, surface mount |
| Operating temperature | 160 °C maximum |
| RoHS | Compliant (-R suffix) |
Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.
For a DC-DC output filter this is the part that decides whether the noise stays inside the conducted limits, and how much margin the design keeps at the top of the load step. 88 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 3.95 A Irms rating is not the thing limiting the design.
CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。
The 88 uH of common-mode inductance is what blocks the noise; the 0.85 uH of leakage inductance is what gets past, and the 3.5 pF of interwinding capacitance is what couples across the windings at high frequency. CMS3 is the largest CMS footprint, with the lowest DCR of the three
Is this part RoHS compliant?
Yes - the -R suffix denotes the RoHS build.
Is this part RoHS compliant?
Yes - the -R suffix denotes the RoHS build.
Why are there two DCR values?
The CMS series specifies each winding separately, measured between (1-2) and between (4-3).
Design note: pick the choke by impedance at the noise
frequency, then confirm DCR and rated current against the signal or the rail.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd