Eaton CMS3-6-R: 217 uH common-mode inductor, 2.85 A Irms, 0.02 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS3-6-R Surface-Mount Common-Mode Choke 217 uH

    CMS3-6-R at a glance: 217 uH common-mode inductor, 2.85 A Irms, 0.02 ohm DCR, surface mount.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS3-6-R
    Open circuit inductance (OCL)217 uH minimum, (1-2) & (4-3)
    I rms (max)2.85 A
    DCR typical @ 20 °C (1-2)0.02 ohm
    DCR typical @ 20 °C (4-3)0.02 ohm
    Leakage inductance typ1.9 uH
    Interwinding capacitance typ3.9 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.

    Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 217 uH is a high-inductance part with a correspondingly low 2.85 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 2.85 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.02 ohm of DCR the winding loss at that current is 0.16 W. CMS3 is the largest CMS footprint, with the lowest DCR of the three

    Frequently Asked Questions

    What impedance should I pick?
    The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.