Eaton CPLA-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor
Eaton CPLA-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

Eaton CPLA-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

Share
Eaton CPLA-3-50TR-R: Multi-Phase Coupled Power Inductor, Acoustic Dampened, 50 nH per phase, 40 A, DCR 0.5 mOhm.
    • Product Details
    • Download

    Eaton CPLA-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

    CPLA-3-50TR-R at a glance: 3-phase coupled inductor, 50 nH per phase, DCR 0.5 mOhm, 40 A rated per phase.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCPLA-3-50TR-R
    Number of phases3
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.5 mOhm
    DCR maximum @ 25 °C0.6 mOhm
    Rated current per phase40 A
    OCL, per pin pair490 nH typical / 365 nH minimum
    Magnetising inductance @ 5 Adc400 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    A multiphase coupled inductor shares one core between the phases, so the phase currents see a mutual inductance as well as their own. With the right phase relationship the ripple partially cancels, and the output capacitor sees less AC current than the sum of the phases would suggest.

    In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    Positioning in the Range

    CPLA is the acoustic-noise-damped version of the 50 nH CPL. Same electrical behaviour, different construction, so the magnetostriction that makes a coupled inductor sing at the switching frequency is suppressed.

    • Typical applications: Noise-sensitive multiphase VRMs, Vcore rails in equipment with acoustic limits.
    • CPLA is not electrically interchangeable with CPL for every controller - the dampening changes the mechanical build; confirm with the reference design.
    • Data sheet 4362.

    Putting It to Work

    50 nH per phase sits at the design point the controller expects of the range, and the trade at that point is explicit: 0.5 mOhm of DCR against - A of saturation headroom.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Can I use it with any multiphase controller?
    No. Eaton specifies these families for Volterra or Maxim VPR devices, and the coupling is part of the reference design. Check the controller before you substitute.

    What does "coupled" change electrically?
    The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.

    What current does the rating refer to?
    Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.