Eaton CTX01-18754-R - 2 nH Coupled VRM Inductor
Eaton CTX01-18754-R - 2 nH Coupled VRM Inductor

Eaton CTX01-18754-R - 2 nH Coupled VRM Inductor

Share
Eaton CTX01-18754-R: Coupled Power Inductor, 2 nH, 50 A, DCR 120 mOhm.
    • Product Details
    • Download

    Eaton CTX01-18754-R - 2 nH Coupled VRM Inductor

    CTX01-18754-R at a glance: coupled power inductor, OCL 2 nH, DCR 120 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberCTX01-18754-R
    Open circuit inductance (OCL), 0 Adc2 nH
    Full load inductance (FLL), minimum60 nH
    Irms50 A
    Isat132 A
    Isat2200 A
    DCR typical @ 20 °C120 mOhm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    The Figures Explained

    Coupled power inductors for VRM applications are specified as a set with the controller: the turns ratio, the coupling coefficient and the saturation behaviour all feed into the loop. Replacing one with a similar-looking part is not a safe substitution.

    The data sheet gives OCL and FLL separately because the core is biased in use. Select on FLL for steady-state ripple, on OCL to identify the part, and on the isolation rating for anything that crosses a boundary.

    Coupling is only useful inside the controller it was designed for. Outside that loop the mutual inductance can add to the ripple instead of cancelling it.

    What This Family Is For

    CTX01-18754 is a 12.7 x 12.05 x 3.0 mm coupled inductor intended for Maxim multiphase controllers. The two windings are coupled on one core, so the phases share flux and the ripple cancels.

    • Typical applications: Multiphase regulators using Maxim controllers, point-of-load, Vcore rails.
    • Eaton lists this part for exclusive use with Maxim multiphase controllers - the coupling ratio is part of the loop design.
    • Data sheet 4420.

    Putting It to Work

    2 nH sits at the design point the controller expects of the range, and the trade at that point is explicit: 120 mOhm of DCR against 32 A of saturation headroom.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the operating temperature?
    -40 °C to +125 °C, ambient plus self-temperature rise.

    Should I use OCL or FLL for the ripple calculation?
    FLL. OCL is measured at zero bias; under load the core is biased and the inductance drops to the full-load value.

    Can I substitute a different coupled inductor?
    Only with the controller vendor's approval. The coupling and the ratio are part of the loop compensation.

    Design note: the loop compensation assumes this coupling. Do not substitute a part with a different ratio without the controller vendor's blessing.

    Mechanical Dimensions

    eaton-ctx01-18754-r-coupled-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.