Eaton CTX10-4P-R Toroid Power Inductor
Eaton CTX10-4P-R Toroid Power Inductor

Eaton CTX10-4P-R Toroid Power Inductor

Share
CTX10-4P-R: toroid power inductor, 9.88 uH.
    • Product Details
    • Download

    Eaton CTX10-4P-R Toroid Power Inductor

    CTX10-4P-R at a glance: toroid power inductor, 9.88 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX10-4P-R
    Inductance, parallel9.88 uH
    Inductance, series39.5 uH
    DC current, parallel2.5 A
    DC current, series1.25 A
    DCR, parallel maximum47 mOhm
    DCR, series maximum187 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    A toroid has no air gap in the usual sense: the gap is distributed through the powder core, which is why the saturation curve is soft and why these parts hold inductance further into the current range than a gapped ferrite.

    Parallel gives 9.88 uH at 2.5 A; series gives 39.5 uH at 1.25 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX10 family this is item 4 of 4 in the Eaton catalogue.

    Series Positioning

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.