Eaton CTX100-3P-R Toroid Transformer / Inductor
Eaton CTX100-3P-R Toroid Transformer / Inductor

Eaton CTX100-3P-R Toroid Transformer / Inductor

Share
CTX100-3P-R: toroid power inductor, 101 uH.
    • Product Details
    • Download

    Eaton CTX100-3P-R Toroid Transformer / Inductor

    CTX100-3P-R at a glance: toroid power inductor, 101 uH.

    Specification Table

    ParameterValue
    Orderable part numberCTX100-3P-R
    Inductance, parallel101 uH
    Inductance, series405 uH
    DC current, parallel0.68 A
    DC current, series0.34 A
    DCR, parallel maximum501 mOhm
    DCR, series maximum2 Ohm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Wired as an inductor it filters or stores energy; wired as a transformer it couples two windings on one core. The parallel and series columns on this page are the inductor ratings, and the turns ratio for transformer use is fixed by the construction.

    Parallel gives 101 uH at 0.68 A; series gives 405 uH at 0.34 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX100 family this is item 3 of 4 in the Eaton catalogue.

    Where This Series Fits

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message