Eaton CTX110600-R CCFL Inverter Transformer, 6 W
Eaton CTX110600-R CCFL Inverter Transformer, 6 W

Eaton CTX110600-R CCFL Inverter Transformer, 6 W

Share
CTX110600-R: CCFL inverter transformer, 44 uH, 6 W, 67:1.
    • Product Details
    • Download

    Eaton CTX110600-R CCFL Inverter Transformer, 6 W

    CTX110600-R at a glance: CCFL inverter transformer, 44 uH, 6 W, 67:1.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX110600-R
    Lamp power6 W
    Primary inductance Lp44 uH
    Turns ratio Ns/Np67
    DCR primary maximum160 mOhm
    DCR secondary maximum31 Ohm
    Primary voltage maximum20 V
    Secondary voltage maximum1340 V
    Secondary current maximum0.011 A rms
    Primary voltage, abnormal30 V
    Secondary voltage, abnormal2000 V
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature0 C to +70 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4303

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4303; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The tube needs roughly 1000 to 1500 V to strike and a few milliamps to run, so the secondary winding carries many turns of fine wire. That is why the secondary DCR is quoted in hundreds of ohms while the primary DCR is a fraction of an ohm.

    A 67:1 ratio with 20 V across the primary puts 1340 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.

    The rated 0.011 A rms into 1340 V is about 14.7 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.

    Within the CTX110600 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.

    • The secondary runs at over 1 kV. Creepage, potting and the lead dress are part of the design, not details to fix later.
    • Typical applications: ccfl power supplies.
    • Design note: choose on turns ratio and abnormal voltage first, then check the lamp power against the Pout rating.

    Frequently Asked Questions

    Is the part isolated?
    Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.

    Can I drive the tube from a different inverter?
    Only if the turns ratio and the saturation current match. The transformer is part of the resonant tank; changing the ratio moves the operating point and can push the core into saturation.

    Why is the secondary DCR so high?
    The secondary has many turns of very fine wire to reach 1300 V or more. Resistance scales with turns and inversely with wire area, so a high-ratio secondary inevitably has tens or hundreds of ohms.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message