| Parameter | Value |
|---|---|
| Orderable part number | CTX17-18913-R |
| Open circuit inductance (OCL), 0 Adc | 380 nH |
| OCL at Isat1 | 200 nH |
| OCL at Isat2 | 200 nH |
| Isat1 | 30 A |
| Isat2 | 23 A |
| SCL (saturation current limit) | 100 nH |
| Isat3 | 90 A |
| DCR typical @ 20 °C | 0.3 mOhm |
| Number of phases | 2 |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
This is a coupled inductor built for a specific multiphase controller family. The winding ratio and the coupling are matched to the controller, so the part is chosen by the reference design rather than by inductance alone.
The data sheet gives OCL and FLL separately because the core is biased in use. Select on FLL for steady-state ripple, on OCL to identify the part, and on the isolation rating for anything that crosses a boundary.
Coupling is only useful inside the controller it was designed for. Outside that loop the mutual inductance can add to the ripple instead of cancelling it.
CTX17-18913 is a two-phase coupled inductor with 380 nH minimum at zero bias, falling to 200 nH at the first saturation point. The datasheet gives both saturation knees, which is what a coupled design needs.
At 380 nH this part is at the design point the controller expects of the family. The winding that produces that inductance is also what sets the 0.3 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Should I use OCL or FLL for the ripple calculation?
FLL. OCL is measured at zero bias; under load the core is biased and the inductance drops to the full-load value.
Should I use OCL or FLL for the ripple calculation?
FLL. OCL is measured at zero bias; under load the core is biased and the inductance drops to the full-load value.
Can I substitute a different coupled inductor?
Only with the controller vendor's approval. The coupling and the ratio are part of the loop compensation.
Design note: the loop compensation assumes this coupling. Do not substitute a part with a different ratio without the controller vendor's blessing.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.