Eaton CTX20-10-52-R 16.0 uH Toroid Inductor 1900 V-us
Eaton CTX20-10-52-R 16.0 uH Toroid Inductor 1900 V-us

Eaton CTX20-10-52-R 16.0 uH Toroid Inductor 1900 V-us

Share
CTX20-10-52-R: toroid power inductor, 16.0 uH, 16 A, Isat 21.3 A, DCR – mOhm.
    • Product Details
    • Download

    Eaton CTX20-10-52-R 16.0 uH Toroid Inductor 1900 V-us

    CTX20-10-52-R at a glance: toroid power inductor, 16.0 uH, 16 A, Isat 21.3 A, DCR – mOhm.

    Specification Table

    ParameterValue
    Orderable part numberCTX20-10-52-R
    Horizontal mount versionCTX20-10-52LP-R
    Header mount version21.17
    Inductance16.0 uH ±20%
    Idc16 A
    Isat21.3 A
    Volt-time rating1900 V-us
    Energy at Isat0.007 uJ
    MountingThrough-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4304

    Outline Drawing

    CTX20-10-52-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4304: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    A toroid concentrates the magnetic path in a closed ring, so almost all of the flux stays inside the core. That is why toroids radiate little and why they are used where a filter inductor has to sit next to sensitive circuitry without a shield.

    Saturation is reached at 21.3 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    The core stores about 0.007 µJ at saturation, which is the energy available to bridge a load step before the control loop reacts.

    The volt-time rating is 1900 V-us: the applied volt-second product that produces a defined core loss. Exceed it and the core heats faster than the copper loss alone would suggest.

    Within the CTX20 family this is value 1 of 6, in a range that runs from 16 to 31.5 uH.

    Where This Series Fits

    The toroid family covers microhenry to tens of microhenry at currents up to a few amps, in vertical, horizontal and header-mounted versions of the same core.

    • The winding is exposed; check the insulation against the working voltage before mounting the part against a chassis.
    • Typical applications: filters; buck and boost switches; chokes.
    • Design note: the three mounting variants share one electrical row, so a mechanical change does not require requalifying the magnetics.

    Frequently Asked Questions

    What does the energy column mean?
    The energy stored at saturation current, in microjoules. It is the figure that connects inductance and current into a single transient capability.

    Why do toroids radiate less?
    The magnetic path is closed inside the ring, so almost no flux escapes. That is why a toroid can sit next to sensitive circuitry without a shield.

    Is the inductance stable with DC bias?
    It falls as the core approaches saturation. The DC current column is the rated point; above it the inductance drops faster.