| Parameter | Value |
|---|---|
| Orderable part number | CTX20-2-52-R |
| Horizontal mount version | CTX20-2-52LP-R |
| Header mount version | CTX20-2-52M-R |
| Inductance | 19.6 uH ±20% |
| DCR maximum @ +25 °C | 39.2 mOhm |
| Idc | 3.2 A |
| Isat | 3.2 A |
| Volt-time rating | 9.4 V-us |
| Energy at Isat | 69 uJ |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4304 |

Drawing reproduced from Eaton Technical Data 4304: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The winding on a toroid is distributed around the ring, which keeps the leakage field low and makes the part mechanically stable. The trade is assembly cost: the coil has to be wound through the hole, so toroids are hand- or machine-wound rather than printed.
At 3.2 A the winding dissipates about 0.401 W in copper, using the 39.2 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 3.2 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
The core stores about 69 µJ at saturation, which is the energy available to bridge a load step before the control loop reacts.
The volt-time rating is 9.4 V-us: the applied volt-second product that produces a defined core loss. Exceed it and the core heats faster than the copper loss alone would suggest.
Within the CTX20 family this is value 2 of 6, in a range that runs from 16 to 31.5 uH.
The toroid family covers microhenry to tens of microhenry at currents up to a few amps, in vertical, horizontal and header-mounted versions of the same core.
Why are there three part numbers per row?
Vertical, horizontal and header-mounted versions of the same core and winding. The electrical values are identical; only the mounting differs.
Why are there three part numbers per row?
Vertical, horizontal and header-mounted versions of the same core and winding. The electrical values are identical; only the mounting differs.
Is the inductance stable with DC bias?
It falls as the core approaches saturation. The DC current column is the rated point; above it the inductance drops faster.