Eaton CTX200-3P-R Toroid Inductor, Parallel 200 uH
Eaton CTX200-3P-R Toroid Inductor, Parallel 200 uH

Eaton CTX200-3P-R Toroid Inductor, Parallel 200 uH

Share
CTX200-3P-R: toroid power inductor, 200 uH.
    • Product Details
    • Download

    Eaton CTX200-3P-R Toroid Inductor, Parallel 200 uH

    CTX200-3P-R at a glance: toroid power inductor, 200 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX200-3P-R
    Inductance, parallel200 uH
    Inductance, series800 uH
    DC current, parallel0.6 A
    DC current, series0.3 A
    DCR, parallel maximum731 mOhm
    DCR, series maximum2.92 Ohm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A toroid wound on a distributed-gap core, with two windings that can be wired in parallel or in series. Parallel gives the low inductance and the high current; series gives four times the inductance at half the current. Both ratings are on the data sheet because both are legitimate ways to use the part.

    Parallel gives 200 uH at 0.6 A; series gives 800 uH at 0.3 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX200 family this is item 3 of 4 in the Eaton catalogue.

    What This Family Is For

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.