Eaton CTX210407-R Cold Cathode Lamp Transformer
Eaton CTX210407-R Cold Cathode Lamp Transformer

Eaton CTX210407-R Cold Cathode Lamp Transformer

Share
CTX210407-R: CCFL inverter transformer, 27 uH, 4 W, 86:1.
    • Product Details
    • Download

    Eaton CTX210407-R Cold Cathode Lamp Transformer

    CTX210407-R at a glance: CCFL inverter transformer, 27 uH, 4 W, 86:1.

    Key Specifications

    ParameterValue
    Orderable part numberCTX210407-R
    Lamp power4 W
    Primary inductance Lp27 uH
    Turns ratio Ns/Np86
    DCR primary maximum160 mOhm
    DCR secondary maximum220 Ohm
    Primary voltage maximum15 V
    Secondary voltage maximum1340 V
    Secondary current maximum0.007 A rms
    Primary voltage, abnormal23 V
    Secondary voltage, abnormal2000 V
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature0 C to +70 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4303

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4303; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Lamp inverters are current-fed, so the transformer is chosen on turns ratio and saturation, not on power alone. Two parts with the same wattage can have very different ratios and will not interchange.

    A 86:1 ratio with 15 V across the primary puts 1290 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.

    The rated 0.007 A rms into 1340 V is about 9.38 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.

    Within the CTX210407 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.

    • The secondary runs at over 1 kV. Creepage, potting and the lead dress are part of the design, not details to fix later.
    • Typical applications: ccfl power supplies.
    • Design note: choose on turns ratio and abnormal voltage first, then check the lamp power against the Pout rating.

    Frequently Asked Questions

    Is the part isolated?
    Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.

    What is the abnormal condition rating for?
    It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.

    What is the abnormal condition rating for?
    It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.