Eaton CTX210609-R CCFL Transformer, 1340 V Output
Eaton CTX210609-R CCFL Transformer, 1340 V Output

Eaton CTX210609-R CCFL Transformer, 1340 V Output

Share
CTX210609-R: CCFL inverter transformer, 20 uH, 6 W, 100:1.
    • Product Details
    • Download

    Eaton CTX210609-R CCFL Transformer, 1340 V Output

    CTX210609-R at a glance: CCFL inverter transformer, 20 uH, 6 W, 100:1.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX210609-R
    Lamp power6 W
    Primary inductance Lp20 uH
    Turns ratio Ns/Np100
    DCR primary maximum132 mOhm
    DCR secondary maximum176 Ohm
    Primary voltage maximum13 V
    Secondary voltage maximum1340 V
    Secondary current maximum0.011 A rms
    Primary voltage, abnormal23 V
    Secondary voltage, abnormal2000 V
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature0 C to +70 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4303

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4303; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A CCFL inverter transformer drives a cold cathode fluorescent tube: the primary sees a few tens of volts from the Royer or push-pull stage, the secondary produces the strike voltage, and the turns ratio sets both. The numbers on this page are the design inputs for that stage, not marketing figures.

    A 100:1 ratio with 13 V across the primary puts 1300 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.

    The rated 0.011 A rms into 1340 V is about 14.7 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.

    Within the CTX210609 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.

    • The secondary runs at over 1 kV. Creepage, potting and the lead dress are part of the design, not details to fix later.
    • Typical applications: ccfl power supplies.
    • Design note: choose on turns ratio and abnormal voltage first, then check the lamp power against the Pout rating.

    Frequently Asked Questions

    What does the Pout rating mean?
    It is the lamp power the part is designed for, which sets the core size and the wire gauge. Running a 2.5 W part at 6 W will overheat the winding even if the voltage rating is met.

    What is the abnormal condition rating for?
    It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.

    Can I drive the tube from a different inverter?
    Only if the turns ratio and the saturation current match. The transformer is part of the resonant tank; changing the ratio moves the operating point and can push the core into saturation.