CTX8-4P-R: toroid power inductor, 7.81 uH.
    • Product Details
    • Download

    Eaton CTX8-4P-R Toroid Transformer / Inductor

    CTX8-4P-R at a glance: toroid power inductor, 7.81 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCTX8-4P-R
    Inductance, parallel7.81 uH
    Inductance, series31.2 uH
    DC current, parallel3 A
    DC current, series1.5 A
    DCR, parallel maximum33 mOhm
    DCR, series maximum131 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    A toroid has no air gap in the usual sense: the gap is distributed through the powder core, which is why the saturation curve is soft and why these parts hold inductance further into the current range than a gapped ferrite.

    Parallel gives 7.81 uH at 3 A; series gives 31.2 uH at 1.5 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX8 family this is item 4 of 4 in the Eaton catalogue.

    What This Family Is For

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.